2018 Abstracts

Abstracts to be presented on Ceocor Congress 2018 Stratford upon Aven

Requirements for intelligent a.c. mitigation devices, that minimize the negative effects of electromagnetic interferences on pipelines

Tobias BRAUN
DEHN + SOEHNE GmbH + Co.KG., Germany, tobias.braun@dehn.de

Corrosion at isolating joints due to cathodic protection

Dr David Buxton
PhD, MICorr Principal Engineer
Dr D G John PhD, FICorr, CEng, CSci, CChem, MRSC
Director – Consultancy Services
Intertek Production & Integrity Assurance,
Manchester Technology Centre,
Units 12-15, Longwood Road,

Electrical resistance sensors for the determination of the protection potential of buried structure under cathodic protection

E. Diler [1], J. Vittonato [2], F. Castillon [3] and N. Larché [1]
[1] Institut de la Corrosion, Brest, France
[2] Total, Pau, France
[3] Transport Infrastructures Gaz France (TIGF), Pau, France

Reference Cell Contamination

Marcus Hardy, Cathodic protection Co Limited

Developments in remote magnetic monitoring of carbon steel pipelines to locate and measure abnormal stress.

Paul Jarram Mayden House

Challenges in developing coupon DC current density-controlled impressed current cathodic protection system for buried steel pipelines

Fumio Kajiyama, Dr.
Tokyo Gas Co., Ltd., 5-20, Kaigan, 1-Chome, Minato-ku, Tokyo, 105-8527, Japan

Realistic Modelling of HVAC Interference on the Pipelines

Himanshu Negi, Electrical Engineer,
Arcadis Consulting UK Ltd.
The Torus Building, Rankine Avenue, Scottish Enterprise Tech. Park, East Kilbride, Scotland
Email: Himanshu.Negi@Arcadis.com
Lewis Smith,Senior Engineer,
Arcadis Consulting UK Ltd.
The Torus Building, Rankine Avenue, Scottish Enterprise Tech. Park, East Kilbride, Scotland
Email: Lewis.Smith@Arcadis.com

STRAY CURRENT INDUCED CORROSION OF STEEL FIBRE REINFORCED CONCRETE

Kangkang Tang(1)
(1) Faculty of Science and Engineering, University of Wolverhampton, UK

THE PROTECTION POTENTIAL – WHAT IS THE EVIDENCE?

Chris Googan
Anticorrosion Engineering Limited
Much Wenlock, England

External soil corrosion failure analysis of gas condensate steel Pipeline”

Names: Hisham. A. Mahfud and Khalifa Abousouh
Affiliation : “Libyan Petroleum Institute (LPI)” )” Km 7, Gergarish Road, P O Box 6431
Tripoli, Libya

Influence of microstructure and heat treatment on corrosion in new low-lead and lead-free brass alloys

Olivier Rod 
Swerea KIMAB

Corrosion protection through cathodic polarization: A discussion of the relevant effects and comparison with literature

M. Büchler
SGK, Swiss Society for Corrosion Protection, Technoparkstrasse 1, CH-8005 Zurich,
Switzerland

2018 BUXTON JOHN Corrosion at isolating joints due to Cathocid protection

Dr David Buxton
PhD, MICorr Principal Engineer
Dr D G John PhD, FICorr, CEng, CSci, CChem, MRSC
Director – Consultancy Services
Intertek Production & Integrity Assurance,
Manchester Technology Centre,

Corrosion monitoring trials to understand the effect of changing water sources on existing water transport infrastructure.

Andrew Brown, Steve Turgoose & Gareth John
Intertek Production & Integrity Assurance

The effectiveness of cathodic protection under shielding conditions - Factory applied coatings

D. Joos and M. Büchler
SGK, Swiss Society for Corrosion Protection, Technoparkstrasse 1, CH-8005 Zurich,

RECENT EXPERIENCES WITH FLAME SPRAYED PE AND PP FIELD JOINT COATING

Ian Laing PhD, MSc, BSc, NACE SCT, CIP Lv. 3
Principal Engineer
Head of Corrosion Group Services

Observations in the Assessment of Microbiologically Influenced Corrosion

Stephen Loftus

Advantages in using remote monitoring to assess effectiveness of Cathodic Protection in stray current affected areas

I.MAGNIFICO
Automa S.r.l. – Via Casine di Paterno, snc – 60131 Ancona - Italia

Evaluating the AC corrosion risk of cathodically protected pipelines -A first experience with a new approach according to German standard GW28-

Ashokanand Vimalanandan*, Markus Büchler+ and Hanns-Georg Schöneich*
* Open Grid Europe GmbH, Gladbecker Str. 404, 45326 Essen, Germany
+ Swiss Society for Corrosion Protection (SGK), Technoparkstr. 1, CH8005 Zürich, Switzerland

SELF ADHESIVE PROTECTIVE COATINGS FOR ENGINEERING AND CONSTRUCTION

Luc Perrad
Manager ExParTech
Polyguard Representative
luc.perrad@expartech.com